{"id":1815,"date":"2013-12-28T16:58:17","date_gmt":"2013-12-28T16:58:17","guid":{"rendered":"http:\/\/ap.msurl.net\/blog\/?page_id=1815"},"modified":"2026-02-16T14:43:38","modified_gmt":"2026-02-16T14:43:38","slug":"service-guidelines-prices","status":"publish","type":"page","link":"https:\/\/www.apdiving.eu\/de\/service\/service-guidelines-prices\/","title":{"rendered":"Service Guidelines &#038; Prices"},"content":{"rendered":"<div id=\"pl-1815\"  class=\"panel-layout\" ><div id=\"pg-1815-0\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-0-0\"  class=\"panel-grid-cell panel-grid-cell-empty\" ><\/div><div id=\"pgc-1815-0-1\"  class=\"panel-grid-cell panel-grid-cell-mobile-last\" ><div id=\"panel-1815-0-1-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child\" data-index=\"0\" ><div class=\"textwidget\"><h1 style=\"text-align: center;\">AP DIVING WARTUNGSPREISE UND -RICHTLINIEN<\/h1><p>Wir nutzen diese Richtlinien um die Kosten f\u00fcr Reparatur und Wartung Ihrer Tauchausr\u00fcstung abzusch\u00e4tzen. Bitte beachten Sie, dass jedes Teil einzeln beurteilt und dann bearbeitet wird, damit kann der Endbetrag tats\u00e4chlich etwas h\u00f6her ausfallen. Falls dies eintritt, werden wir immer mit Ihnen Kontakt aufnehmen, bevor wir uns an die Arbeit machen. Diese Auflistung erhebt keinen Anspruch auf Vollst\u00e4ndigkeit und wir k\u00f6nnen auch weitere Wartungsma\u00dfnahmen auf spezifische Anfragen hin durchf\u00fchren.<\/p><\/div><\/div><div id=\"panel-1815-0-1-1\" class=\"so-panel widget widget_sow-image panel-last-child\" data-index=\"1\" ><div class=\"panel-widget-style panel-widget-style-for-1815-0-1-1\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-8b5b6f678277-1815\"\n\t\t\t\n\t\t>\n\n<div class=\"sow-image-container\">\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg\" width=\"970\" height=\"20\" srcset=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg 970w, https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3-300x6.jpg 300w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" title=\"separator-middle\" alt=\"\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><\/div><div id=\"pgc-1815-0-2\"  class=\"panel-grid-cell panel-grid-cell-empty\" ><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-1\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1815-1-0-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child\" data-index=\"2\" ><div class=\"textwidget\"><h2>AP JACKET WARTUNG<\/h2>\n<p><strong>Alle unten aufgef\u00fchrten Jacket-Wartungspreise beinhalten MwSt aber keinen R\u00fcckversand.<\/strong> Bitte kontaktieren Sie uns f\u00fcr die Versandkosten zu Ihrer Adresse.<\/p>\n<p>BITTE BEACHTEN SIE: Wenn Sie Ihr Tarierjacket zur Wartung einsenden, tun Sie dies unter der Voraussetzung, dass die Beurteilung eine vollst\u00e4ndige Demontage des Tarierjackets einschlie\u00dflich der Entfernung der Ventile und der Blase erfordert. Das BCD wird bei der Ankunft beurteilt und alle zus\u00e4tzlichen Wartungs-, Ersatzteil- oder Reparaturkosten werden mit dem Kunden besprochen und vereinbart, bevor weitere Arbeiten durchgef\u00fchrt werden.<\/p>\n<p>Nachbeurteilung \u2013 wenn Sie mit der Wartung nicht fortfahren m\u00f6chten oder sich herausstellt, dass die Jacke nicht mehr reparierbar ist:<\/p>\n<ul>\n<li>Wir pr\u00fcfen, ob der\/die Fehler durch die Garantie abgedeckt sind (siehe Bedingungen unten)<\/li>\n<\/ul>\n<p>Wenn Sie keinen Anspruch auf Garantie haben, haben Sie folgende M\u00f6glichkeiten:<\/p>\n<ol>\n<li>Sie verlangen, dass wir Ihnen die Teile per Post zusenden (gegen Portokosten)<\/li>\n<li>Sie beantragen, dass wir das Tarierjacket verschrotten (mit dem Angebot eines Abwrackrabatts auf ein neues AP-Jackenjacket).<\/li>\n<li>Sie verlangen, dass wir das Tarierjacket wieder zusammenbauen und zur\u00fccksenden.* Es f\u00e4llt eine Wiederzusammenbaugeb\u00fchr von 52,43 \u20ac zzgl. Porto an.<\/li>\n<\/ol>\n<h6>*Diese Option ist nur verf\u00fcgbar, wenn ein erneuter Zusammenbau physisch m\u00f6glich ist. Der Zusammenbau erfolgt unter der Voraussetzung, dass kein Inflationstest durchgef\u00fchrt wird und das BCD mit dem Hinweis zur\u00fcckgeschickt wird, dass es besch\u00e4digt\/undicht usw. ist, und dass die zuk\u00fcnftige Verwendung des BCD daher ausschlie\u00dflich auf Risiko des Besitzers erfolgt.<\/h6>\n<p>Wenn Sie mit der Wartung fortfahren: Der Preis f\u00fcr die BCD-Wartung beinhaltet das vollst\u00e4ndige Zerlegen und Reinigen, die Desinfektion der inneren Blase, den Austausch aller anderen BCD-Ventile durch brandneue Ventile beim Zusammenbau und einen 6-st\u00fcndigen F\u00fclltest. Kleinere Pannenreparaturen (bis zu 5) sind im Service inbegriffen.<\/p>\n<p><div class=\"table-responsive\"><table  style=\"width:100%; \"  class=\"easy-table easy-table-ap \" >\n<tbody>\r\n<tr><td  style=\"width:80px\" >Jacket Wartung<\/td>\n<td  style=\"width:300px\" >Der Inflator\/Auto Air und Emergency Air Cylinder (Notfallflasche) ist nicht in den Kosten des BCD-Service enthalten. F\u00fcr diese fallen zus\u00e4tzliche Kosten an, wie in der folgenden Tabelle angegeben. Der BCD wird bei Ankunft bewertet und zus\u00e4tzliche Wartungs-, Ersatzteil- oder Reparaturkosten werden mit dem Kunden besprochen und vereinbart, bevor weitere Arbeiten durchgef\u00fchrt werden. Der BCD-Servicepreis beinhaltet den Austausch aller anderen BCD-Ventile durch brandneue Teile beim Zusammenbau und einen Inflationstest \u00fcber Nacht.<\/td>\n<td  style=\"width:80px\" >144,20 \u20ac +pp<\/td>\n<\/tr>\n\r\n<tr><td >Auto Air-Wartung und Schlauch<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern, Austausch von O-Ringen, Maschen, Schraeder-Ventilen, Mundst\u00fcck und anderen verschlissenen Teilen. Zusammenbau und Funktionstest.<\/td>\n<td >52,43 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >AP200\/APV200\/APV300 Inflator-Wartung und Schlauch<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern, Austausch von O-Ringen, Maschen, Schraeder-Ventilen, Mundst\u00fcck und anderen verschlissenen Teilen. Zusammenbau und Funktionstest.<\/td>\n<td >35,39 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Jacketflasche &amp; Ventil-Wartung<\/td>\n<td >Beinhaltet die Wartung des Notfallflaschenventils und Pr\u00fcfung der Flasche. Jacketflaschen (Miniflaschen) sollten alle 5 Jahre gem\u00e4\u00df den Vorschriften aus dem Jahr 2003 \u00fcberpr\u00fcft werden und so wie jede andere Pressluftflasche einen Stempel mit dem Pr\u00fcfdatum erhalten. Alternativ und im Interesse h\u00f6chster Sicherheit k\u00f6nnen Sie auch von unserem Alt-gegen-Neu Flaschenaustauschprogramm Gebrauch machen.<\/td>\n<td >38,02 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Jacketflaschen-Austausch<\/td>\n<td >Wir tauschen Ihre alte Flasche gegen eine neue aus und warten das Ventil.<\/td>\n<td >110,11 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >AP Blast Air-Horn (Signalhorn)-Wartung und Schlauch<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern, Austausch von O-Ringen, Schraeder-Ventilen, und anderen verschlissenen Teilen. Zusammenbau und Funktionstest.<\/td>\n<td >45,88 \u20ac<\/td>\n<\/tr>\n<\/tbody><\/table><\/div><\/p>\n<\/div><\/div><div id=\"panel-1815-1-0-1\" class=\"so-panel widget widget_sow-image panel-last-child\" data-index=\"3\" ><div class=\"panel-widget-style panel-widget-style-for-1815-1-0-1\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-8b5b6f678277-1815\"\n\t\t\t\n\t\t>\n\n<div class=\"sow-image-container\">\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg\" width=\"970\" height=\"20\" srcset=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg 970w, https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3-300x6.jpg 300w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" title=\"separator-middle\" alt=\"\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-2\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-2-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1815-2-0-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child\" data-index=\"4\" ><div class=\"textwidget\"><h2 style=\"text-align: left;\">\u00a0<\/h2>\n<h2>AP REBREATHER WARTUNG<\/h2>\n<p><strong>Alle unten aufgef\u00fchrten Rebreather-Wartungspreise beinhalten MwSt aber <em>keinen<\/em> R\u00fcckversand.<\/strong> Bitte kontaktieren Sie uns f\u00fcr die Versandkosten zu Ihrer Adresse.<\/p>\n<p><div class=\"table-responsive\"><table  style=\"width:100%; \"  class=\"easy-table easy-table-ap \" >\n<tbody>\r\n<tr><td  style=\"width:100px\" >Gegenlungen<\/td>\n<td  style=\"width:760px\" >Vollst\u00e4ndige Demontage, Reinigung, Austausch von Dichtungen, Leckagetests der inneren Beutel und Reparatur\/Austausch nach Notwendigkeit zu zus\u00e4tzlichen Kosten. Die \u00e4u\u00dferen Beutel werden ebenfalls gepr\u00fcft und vor der Endmontage ggf. repariert. Abschlie\u00dfende Leckagetests, um sicherzustellen, dass die Gegenlungen wieder arbeiten wie neu.<\/td>\n<td  style=\"width:100px\" >48,55 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Wing<\/td>\n<td >Vollst\u00e4ndige Demontage und Reinigung, Austausch von Dichtungen, Leckagetests der inneren Blase und Reparatur\/Austausch nach Notwendigkeit zu zus\u00e4tzlichen Kosten. Die \u00e4u\u00dferen Beutel werden ebenfalls gepr\u00fcft und vor der Endmontage ggf. repariert. Abschlie\u00dfende Leckagetests, um sicherzustellen, dass Wing arbeitet wie neu.<\/td>\n<td >111,42 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Geh\u00e4use<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern und \u00dcberpr\u00fcfen aller Komponenten \u2013 wenn Ersatzteile ben\u00f6tigt werden, fallen Extrakosten an.\u00a0Entfernung von ADV, Inflatoren und allen Schl\u00e4uchen. Datumskontrolle und gr\u00fcndliche Inspektion aller Schl\u00e4uche, Verteiler und Manometer. Durchgehend reinigen, O-Ringe ersetzen und wieder aufbauen. Drucktest.<\/td>\n<td >73,02 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Open Circuit Bailout-Ventil (OCB)<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern und \u00dcberpr\u00fcfen aller Komponenten \u2013 wenn Ersatzteile ben\u00f6tigt werden, fallen Extrakosten an. Austausch von Dichtungen und Richtungsventilen, Anpassung des Sitzes des Mundst\u00fccks f\u00fcr reibungslosen und ordnungsgem\u00e4\u00dfen Betrieb.<\/td>\n<td >55,70 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Mundst\u00fcck<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern und \u00dcberpr\u00fcfen aller Komponenten \u2013 wenn Ersatzteile ben\u00f6tigt werden, fallen Extrakosten an. Austausch von Dichtungen und Richtungsventilen, Anpassung des Sitzes des Mundst\u00fccks f\u00fcr reibungslosen und ordnungsgem\u00e4\u00dfen Betrieb.<\/td>\n<td >31,22 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Inflatoren (paarweise)<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern, Austausch von Dichtungen und Filtern und Zusammenbau. Funktionstest.<\/td>\n<td >41.31 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Automatic Diluent Valve - Automatisches Verd\u00fcnnungsgas-Ventil (ADV)<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern, Austausch von Dichtungen, Membran, Filter und Zusammenbau. Funktionstest.<\/td>\n<td >46,82 \u20ac<\/td>\n<\/tr>\n\r\n<tr><td >Erste Stufen (jeweils)<\/td>\n<td >Vollst\u00e4ndige Demontage, S\u00e4ubern, Austausch von Dichtungen, Ventilanschl\u00fcssen, Membran, Filter. Zusammenbau und spezielle Einstellung auf den Einsatz im Rebreather.<\/td>\n<td >70,56 \u20ac<\/td>\n<\/tr>\n<\/tbody><\/table><\/div><\/p>\n<p>&nbsp;<\/p>\n<h4>Mitteldruck- und Hochdruckschl\u00e4uche<\/h4>\n<p><strong>Abh\u00e4ngig vom Gebrauch ist es ratsam, die Sauerstoffschl\u00e4uche alle 5-6 Jahre und alle Diluent-\/Luftschl\u00e4uche alle 8\u00a0Jahre zu erneuern.<\/strong><\/p>\n<p>Die Schl\u00e4uche k\u00f6nnen in G\u00e4nze also mit ihren Anschl\u00fcssen erneuert werden oder die Anschl\u00fcsse k\u00f6nnen demontiert, gereinigt und gepr\u00fcft und auf die neuen Schl\u00e4uche montiert werden.<\/p>\n<p>&nbsp;<\/p>\n<\/div><\/div><div id=\"panel-1815-2-0-1\" class=\"so-panel widget widget_sow-image\" data-index=\"5\" ><div class=\"panel-widget-style panel-widget-style-for-1815-2-0-1\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-8b5b6f678277-1815\"\n\t\t\t\n\t\t>\n\n<div class=\"sow-image-container\">\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg\" width=\"970\" height=\"20\" srcset=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg 970w, https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3-300x6.jpg 300w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" title=\"separator-middle\" alt=\"\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><div id=\"panel-1815-2-0-2\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce\" data-index=\"6\" ><div class=\"textwidget\"><h3>\u00a0<\/h3>\n<h3 style=\"text-align: center;\"><strong>WICHTIGER HINWEIS:<\/strong><b><\/b><\/h3>\n<h3 style=\"text-align: center;\"><strong><br \/>\nEinsendung einer Inspiration Elektronik zur Wartung<br \/>\nvon au\u00dferhalb des V.K. <\/strong><\/h3>\n<p><span lang=\"DE\">F\u00fcr alle Produkte, die von au\u00dferhalb des V.K. - einschlie\u00dflich aller EU-L\u00e4nder (Siehe Hinweis unten \"Versand aus der EU\")* - an AP Diving zur\u00fcckgesandt werden, muss an der Au\u00dfenseite des Pakets eine \u201eReferenzrechnung - R\u00fccksendung zur Wartung\u201c angebracht sein, die zur Zollkontrolle zur Verf\u00fcgung steht. Bei einigen Versanddiensten m\u00fcssen Sie diesen auch eine Kopie dieser Rechnung per E-Mail zusenden. Bitte wenden Sie sich an Ihren Versanddienst, um Ratschl\u00e4ge zu deren Verfahren zu erhalten.<\/span><\/p>\n<p>Bitte laden Sie unten das Rechnungsformular f\u00fcr die R\u00fcckgabe des Elektronik zur Wartung herunter und f\u00fcgen Sie Ihre Daten an den entsprechenden Stellen ein.<\/p>\n<p>&nbsp;<\/p>\n<p><a href='https:\/\/www.apdiving.com\/en\/?ddownload=11957' onclick='' class='wpi_designer_button   wpi_shadow wpi_shadow_no wpi_text_shadow_no wpi_texture_no wpi_border_bottom wpi_padding_15px wpi_5px wpi_designer_button_8129 wpi_icon wpi_icon_download wpi_icon_left  ' target='_blank' rel=''><i class=''><\/i><span class='wpi_text'>Rechnungsformular f\u00fcr die R\u00fcckgabe des Elektronik <\/span><\/a><\/p>\n<p>&nbsp;<\/p>\n<h3 style=\"text-align: center;\"><strong>Einsendung von anderen AP-Produkten zur Wartung<br \/>\nvon au\u00dferhalb des V.K.<\/strong><\/h3>\n<p>Bitte laden Sie unten das Rechnungsformular zur Wartung herunter und f\u00fcgen Sie Ihre Daten an den entsprechenden Stellen ein (oder verwenden Sie, falls verf\u00fcgbar, ein von Ihrem Versanddienst bereitgestelltes Musterformular).<\/p>\n<p>&nbsp;<\/p>\n<p><a href='https:\/\/www.apdiving.com\/en\/?ddownload=10277' onclick='' class='wpi_designer_button   wpi_shadow wpi_shadow_no wpi_text_shadow_no wpi_texture_no wpi_border_bottom wpi_padding_15px wpi_5px wpi_designer_button_8129 wpi_icon wpi_icon_download wpi_icon_left  ' target='_blank' rel=''><i class=''><\/i><span class='wpi_text'>Rechnungsformular f\u00fcr die R\u00fcckgabe des Produkt <\/span><\/a><\/p>\n<p>&nbsp;<\/p>\n<\/div><\/div><div id=\"panel-1815-2-0-3\" class=\"so-panel widget widget_sow-image\" data-index=\"7\" ><div class=\"panel-widget-style panel-widget-style-for-1815-2-0-3\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-8b5b6f678277-1815\"\n\t\t\t\n\t\t>\n\n<div class=\"sow-image-container\">\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg\" width=\"970\" height=\"20\" srcset=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg 970w, https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3-300x6.jpg 300w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" title=\"separator-middle\" alt=\"\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><div id=\"panel-1815-2-0-4\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce\" data-index=\"8\" ><div class=\"textwidget\"><h3 style=\"text-align: center;\"><strong>*Versand von Produkten f\u00fcr den Service aus Europa<\/strong><\/h3>\n<h3 style=\"text-align: center;\">Das neue Vertriebszentrum von AP Diving Europe<\/h3>\n<p>\u00a0<\/p>\n<p>\u00a0Ab dem 2. August 2021 k\u00f6nnen europ\u00e4ische Kunden AP-Produkte zum Service direkt an <strong>AP Diving Europe<\/strong> in den Niederlanden zur\u00fccksenden und vermeiden Einfuhrpapiere und Zollabfertigungen, die von unseren Mitarbeitern in Voorschoten erledigt werden.<\/p>\n<p><span style=\"color: #424242;\"><span style=\"font-family: Helvetica W01 Light, serif;\"><span style=\"font-size: large;\">Wenn Sie ein Produkt zur Wartung einsenden aus einem EU-Land an AP Diving senden Sie es bitte ausreichend versichert an die folgende Adresse mit einem Anschreiben, in dem Sie die gew\u00fcnschten Arbeiten beschreiben und Ihre vollst\u00e4ndigen Kontaktdaten angeben:<\/span><\/span><\/span><\/p>\n<p>\u00a0<\/p>\n<p><strong>A.P. Diving Europe B.V.<\/strong><br \/><strong>Industrieweg 30<\/strong><br \/><strong>2254 AE<\/strong><br \/><strong>Voorschoten<\/strong><br \/><strong>Niederlande<\/strong><\/p>\n<p>\u00a0<\/p>\n<p><strong>*BITTE BEACHTEN SIE: Wenn Sie aus irgendeinem Grund Produkte f\u00fcr den Service direkt an AP Diving UK senden m\u00fcssen, m\u00fcssen Sie die hier beschriebenen Verfahren und Formalit\u00e4ten f\u00fcr den \u201evor\u00fcbergehenden Import\u201c befolgen.<\/strong><\/p>\n<p>\u00a0<\/p>\n<\/div><\/div><div id=\"panel-1815-2-0-5\" class=\"so-panel widget widget_sow-image panel-last-child\" data-index=\"9\" ><div class=\"panel-widget-style panel-widget-style-for-1815-2-0-5\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-8b5b6f678277-1815\"\n\t\t\t\n\t\t>\n\n<div class=\"sow-image-container\">\n\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg\" width=\"970\" height=\"20\" srcset=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3.jpg 970w, https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle3-300x6.jpg 300w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" title=\"separator-middle\" alt=\"\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-3\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-3-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1815-3-0-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child panel-last-child\" data-index=\"10\" ><div class=\"textwidget\"><h1 style=\"text-align: center;\">AP REBREATHER ELEKTRONIK-WARTUNG<\/h1>\n<p style=\"text-align: left;\">Es gibt zwei Wartungsstufen f\u00fcr die AP Diving Rebreather-Elektronik, 'Basis- und Komplettwartung'. Nach einer ersten Pr\u00fcfung des Equipments wird entschieden, welcher Wartungslevel erforderlich ist. Wir werden Sie dann kontaktieren, um unsere Pr\u00fcfungsergebnisse und das weitere Vorgehen mit Ihnen zu besprechen.<\/p>\n<\/div><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-4\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-4-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1815-4-0-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child panel-last-child\" data-index=\"11\" ><div class=\"textwidget\"><h3>Basiswartung Classic Elektronik\u00a0 - 91,71 \u20ac<\/h3>\n<p>Die Basiswartung f\u00fcr die Classic Elektronik beinhaltet:<\/p>\n<ol>\n<li>Ausbau der Sensorhalterung, Erneuerung des O-Rings<\/li>\n<li>Ausbau der Sauerstoffsensoren und Inspektion. Falls \u00fcberaltert oder fehlerhaft empfehlen wir die Erneuerung<\/li>\n<li>Inspektion der Molex- oder Koaxial-Anschl\u00fcsse der Sensoren und des Zustand der Kabelstr\u00e4nge\u00a0<\/li>\n<li>Ausbau von Solenoid (Magnetventil) und den zugeh\u00f6rigen Anschl\u00fcssen, Inspektion, Reinigung und\u00a0 \u00a0Durchflusstest<\/li>\n<li>\u00dcberpr\u00fcfung der Buzzer-Kabelanschl\u00fcsse und Erneuerung des O-Rings am Buzzerschlauch<\/li>\n<li>\u00dcberpr\u00fcfung der Batteriebox<\/li>\n<li>Zusammenbau des Sensorikkopfes und Montage eines neuen O-Rings<\/li>\n<li>Pr\u00fcfung der Magnetschalter am Handset auf Zustand und Funktionsf\u00e4higkeit\u00a0<\/li>\n<li>Leckage- und Funktionspr\u00fcfung unter 1,3 bar<\/li>\n<li>Die gewartete Elektronik erh\u00e4lt 2 neue Batterien (gilt nur f\u00fcr Modelle mit Einwegbatterien)<\/li>\n<\/ol>\n<\/div><\/div><\/div><div id=\"pgc-1815-4-1\"  class=\"panel-grid-cell\" ><div class=\"vg-image-widget\"><img decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/de-rebreather-electronics-service-type-basic-classic.jpg\" alt=\"\"\/><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-5\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-5-0\"  class=\"panel-grid-cell\" ><div class=\"vg-image-widget\"><img decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/de-rebreather-electronics-service-type-full-classic.jpg\" alt=\"\"\/><\/div><\/div><div id=\"pgc-1815-5-1\"  class=\"panel-grid-cell\" ><div id=\"panel-1815-5-1-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child panel-last-child\" data-index=\"14\" ><div class=\"textwidget\"><h3>Komplettwartung Classic Elektronik - 275,12 \u20ac<\/h3>\n<ol>\n<li>Falls wir bei der Anfangspr\u00fcfung Hinweise auf Flutungen oder einen Fehler finden, der den Ausbau eines elektronischen Moduls oder die Erneuerung von Kabelstr\u00e4ngen erfordert, dann ist eine Komplettwartung notwendig, die zus\u00e4tzlich zur Basiswartung folgendes beinhaltet:<\/li>\n<li>Erneuerung des Handset-Geh\u00e4uses\u00a0<\/li>\n<li>Anpassung neuer on\/off-Magnetschalter am Handset<\/li>\n<li>Ausbau der elektronischen Module, \u00dcberpr\u00fcfung und Wiedereinbau, falls funktionst\u00fcchtig<\/li>\n<li>Ausbau und Reinigung aller Schl\u00e4uche und Erneuerung der O-Ringe\u00a0<\/li>\n<li>Ausbau und Reinigung aller Anschl\u00fcsse am Sensorikkopf und Erneuerung der O-Ringe<\/li>\n<\/ol>\n<p>Hinweis: Alle w\u00e4hrend der Wartung auszutauschenden und zu erneuernden Bauteile m\u00fcssen zus\u00e4tzlich zu den reinen Wartungskosten in Rechnung gestellt werden.<\/p>\n<\/div><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-6\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-6-0\"  class=\"panel-grid-cell\" ><div class=\"vg-image-widget\"><img decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle.jpg\" alt=\"\"\/><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-7\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-7-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1815-7-0-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child panel-last-child\" data-index=\"16\" ><div class=\"textwidget\"><h3>Basiswartung Vision Elektronik - 91,71 \u20ac<\/h3>\n<p>Zus\u00e4tzlich zur gew\u00f6hnlichen Anfangspr\u00fcfung machen wir ein Backup der Tauchgangsaufzeichnungen und sehen die Rebreather-Daten durch. Die Basiswartung der Vision Elektronik beinhaltet:\u00a0<\/p>\n<ol>\n<li>Ausbau der Sensorhalterung, Erneuerung des O-Rings<\/li>\n<li>Ausbau der Sauerstoffsensoren und Inspektion. Falls \u00fcberaltert oder fehlerhaft empfehlen wir die Erneuerung\u00a0<\/li>\n<li>\u00dcberpr\u00fcfung der Koaxial-Sensoranschl\u00fcsse<\/li>\n<li>\u00dcberpr\u00fcfung des Zustands der Kabelstr\u00e4nge im Sensorikkopf, Handset und Kalkbeh\u00e4lter<\/li>\n<li>Ausbau von Solenoid (Magnetventil) und den zugeh\u00f6rigen Anschl\u00fcssen, Inspektion, Reinigung und Durchflusstest<\/li>\n<li>\u00dcberpr\u00fcfung der Buzzer-Kabelanschl\u00fcsse und Erneuerung des O-Rings am Buzzerschlauch<\/li>\n<li>\u00dcberpr\u00fcfung der Batteriebox\u00a0<\/li>\n<li>Zusammenbau des Sensorikkopfes und Montage eines neuen O-Rings<\/li>\n<li>Funktionstest der Kn\u00f6pfe am Handset\u00a0<\/li>\n<li>Inspektion der Handsetabdeckung und der Armb\u00e4nder<\/li>\n<li>Funktionspr\u00fcfung des HUD (Headup-Display) und ggf. (Helligkeits-)Anpassung der Glasfaseroptik<\/li>\n<li>Funktionspr\u00fcfung der Elektronik<\/li>\n<li>Lackagetests und Pr\u00fcfung der korrekten Kalibrierung und Genauigkeit bei 1.3 bar\u00a0<\/li>\n<li>R\u00fcckgabe der gewarteten Elektronik mit neuen Batterien (gilt nur f\u00fcr Modelle mit Einwegbatterien)<\/li>\n<\/ol>\n<\/div><\/div><\/div><div id=\"pgc-1815-7-1\"  class=\"panel-grid-cell\" ><div class=\"vg-image-widget\"><img decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/de-rebreather-electronics-service-type-basic-vision.jpg\" alt=\"\"\/><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-8\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-8-0\"  class=\"panel-grid-cell\" ><div class=\"vg-image-widget\"><img decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/de-rebreather-electronics-service-type-full-vision.jpg\" alt=\"\"\/><\/div><\/div><div id=\"pgc-1815-8-1\"  class=\"panel-grid-cell\" ><div id=\"panel-1815-8-1-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child panel-last-child\" data-index=\"19\" ><div class=\"textwidget\"><h3>\nKomplettwartung der Vision Elektronik - 146,73 \u20ac<\/h3>\n<p>Falls wir w\u00e4hrend der Anfangspr\u00fcfung die die Anschl\u00fcsse am Sensorikkopf in schlechtem Zustand vorfinden, dann empfehlen wir eine Komplettwartung, die zus\u00e4tzlich zur Basiswartung folgendes beinhaltet:<\/p>\n<ol>\n<li>Ausbau und Reinigung aller Schl\u00e4uche und Erneuerung der O-Ringe<\/li>\n<li>Ausbau und Reinigung aller Anschl\u00fcsse am Sensorikkopf und Erneuerung der O-Ringe<\/li>\n<\/ol>\n<\/div><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-9\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-9-0\"  class=\"panel-grid-cell\" ><div class=\"vg-image-widget\"><img decoding=\"async\" src=\"https:\/\/www.apdiving.eu\/de\/wp-content\/uploads\/separator-middle.jpg\" alt=\"\"\/><\/div><\/div><\/div><!--vgRowWrapper--><\/div><div id=\"pg-1815-10\"  class=\"panel-grid panel-no-style\" ><div class=\"vgRowWrapper\"><div id=\"pgc-1815-10-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1815-10-0-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child panel-last-child\" data-index=\"21\" ><div class=\"textwidget\"><h3>\u00a0<\/h3>\n<h3 style=\"text-align: center;\"><strong>WICHTIGER HINWEIS:<\/strong><b><\/b><\/h3>\n<h3 style=\"text-align: center;\"><strong><br \/>\nEinsendung einer Inspiration Elektronik zur Wartung<br \/>\nvon au\u00dferhalb des V.K. <\/strong><\/h3>\n<p><span lang=\"DE\">F\u00fcr alle Produkte, die von au\u00dferhalb des V.K. - einschlie\u00dflich aller EU-L\u00e4nder (Siehe Hinweis oben \"Versand aus der EU\")* - an AP Diving zur\u00fcckgesandt werden, muss an der Au\u00dfenseite des Pakets eine \u201eReferenzrechnung - R\u00fccksendung zur Wartung\u201c angebracht sein, die zur Zollkontrolle zur Verf\u00fcgung steht. Bei einigen Versanddiensten m\u00fcssen Sie diesen auch eine Kopie dieser Rechnung per E-Mail zusenden. Bitte wenden Sie sich an Ihren Versanddienst, um Ratschl\u00e4ge zu deren Verfahren zu erhalten.<\/span><\/p>\n<p>Bitte laden Sie unten das Rechnungsformular f\u00fcr die R\u00fcckgabe des Elektronik zur Wartung herunter und f\u00fcgen Sie Ihre Daten an den entsprechenden Stellen ein.<\/p>\n<p>&nbsp;<\/p>\n<p><a href='https:\/\/www.apdiving.com\/en\/?ddownload=11957' onclick='' class='wpi_designer_button   wpi_shadow wpi_shadow_no wpi_text_shadow_no wpi_texture_no wpi_border_bottom wpi_padding_15px wpi_5px wpi_designer_button_8129 wpi_icon wpi_icon_download wpi_icon_left  ' target='_blank' rel=''><i class=''><\/i><span class='wpi_text'>Rechnungsformular f\u00fcr die R\u00fcckgabe des Elektronik <\/span><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h3 style=\"text-align: center;\"><strong>Einsendung von anderen AP-Produkten zur Wartung<br \/>\nvon au\u00dferhalb des V.K.<\/strong><\/h3>\n<p>Bitte laden Sie unten das Rechnungsformular zur Wartung herunter und f\u00fcgen Sie Ihre Daten an den entsprechenden Stellen ein (oder verwenden Sie, falls verf\u00fcgbar, ein von Ihrem Versanddienst bereitgestelltes Musterformular).<\/p>\n<p>&nbsp;<\/p>\n<p><a href='https:\/\/www.apdiving.com\/en\/?ddownload=10277' onclick='' class='wpi_designer_button   wpi_shadow wpi_shadow_no wpi_text_shadow_no wpi_texture_no wpi_border_bottom wpi_padding_15px wpi_5px wpi_designer_button_8129 wpi_icon wpi_icon_download wpi_icon_left  ' target='_blank' rel=''><i class=''><\/i><span class='wpi_text'>Rechnungsformular f\u00fcr die R\u00fcckgabe des Produkt <\/span><\/a><\/p>\n<p>&nbsp;<\/p>\n<\/div><\/div><\/div><\/div><!--vgRowWrapper--><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>AP DIVING WARTUNGSPREISE UND -RICHTLINIENWir nutzen diese Richtlinien um die Kosten f\u00fcr Reparatur und Wartung Ihrer Tauchausr\u00fcstung abzusch\u00e4tzen. Bitte beachten Sie, dass jedes Teil einzeln beurteilt und dann bearbeitet wird, damit kann der Endbetrag tats\u00e4chlich etwas h\u00f6her ausfallen. Falls dies eintritt, werden wir immer mit Ihnen Kontakt aufnehmen, bevor wir uns an die Arbeit machen. <a href=\"https:\/\/www.apdiving.eu\/de\/service\/service-guidelines-prices\/\">[Read More &hellip;]<\/a><\/p>\n","protected":false},"author":4,"featured_media":0,"parent":20,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-1815","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/pages\/1815","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/comments?post=1815"}],"version-history":[{"count":10,"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/pages\/1815\/revisions"}],"predecessor-version":[{"id":8506,"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/pages\/1815\/revisions\/8506"}],"up":[{"embeddable":true,"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/pages\/20"}],"wp:attachment":[{"href":"https:\/\/www.apdiving.eu\/de\/wp-json\/wp\/v2\/media?parent=1815"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}